LANmark-8 S/FTP AWG22 Cat 8.2 2000MHz LSZH Dca s2 d2 a1 Orange 1000m Reel
LANmark-8 S/FTP AWG22 Cat 8.2 2000MHz LSZH Dca s2 d2 a1 Orange 1000m Reel
- High Quality Data Cables for Datacentres
- S/FTP Design with dual shielding for optimal protection against EMI and Exogenous Noise (Alien Crosstalk)
- Cable exceeds Category 8
- Superior Performance with positive ACR over the full frequency range up to 80m
- Optimised for use with LANmark GG45 connector
- Reaction-to-fire performance according to CPR classification Dca-s2,d2,a1 (h/EN50575:2014+A1:2016)
- Nexans ref. : N100.481-OD
Description
Description
Standards
-
ProductEN 50173; EN 50288-4-1; ISO/IEC 61156-5
-
InternationalISO/IEC 11801
Description
LANmark-8 S/FTP is a 4 pair AWG22 cable with individual pair foils and an overall braid offering superior performance up to 2000 MHz. The cable is fully compliant with the new Category 8 standards for Datacentres and remain to be Cat7A compliant for Enterpise use. Due to their excellent electrical performance and very low noise levels the cable supports applications like 10GBASE-T over 100m and 25/40GBASE-T over 30m and beyond.
Application
Cat7A/Cat 8 are the highest performing standardised cable specifications for Enterprise market and Datacentre market and and exceed lower cable standards in all parameters. They will therefore support all current data applications and all planned applications using structured cabling up to Class FA or Class I/II. LANmark-8 cables provide therefore the best investment protection of all Twisted Pair cables.
- All Ethernet applications including
- 10/100/1000Base-T
- 1000Base-TX
- 10GBase-T
- 25GBase-T and 40GBase-T (up to 30m, see 802.3bq)
- POE, POE+, POE++ (Draft)
- Cable sharing applications including CATV up to 862MHz
- Any future Class FA, Class I and Class II application
Installation
Improved screening against outside noise sources and ease of installation are the main features of LANmark-8 2G cables. Extra attention has been paid to ensure that the screen coverage is maintained and foils do not open during installation. The cables have been specially designed to be used in conjunction with the LANmark GG45 12C connector.
To support the correct set-up of hand held analysers for installation testing, the actual cable NVP value is given in the cable’s print legend.
Electrical Performance LANmark-8 Cable
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Transmission characteristics
Transmission characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics