TBU LSZH 6x50/125 OM3 SP1724 BK

Description

Description

Standards

  • Product
    IEC 60794
  • Test
    EN 50399 D; IEC 60332-1; IEC 60332-3; IEC 60754-1; IEC 61034

This tight buffer cable is designed for indoor/outdoor installation.

This cable has an outstanding fire behaviour.

Direct connectorization is made easy with 900µm buffered structure.

This cable can be operated under a large temperature range.

 

Design

The TBU LSZH* SP1724 cable has a central strength member (FRP: Fibre Reinforced Plastic), with 6 900µm buffered structure around. The design is reinforced by a layer of glass yarns and a LSZH* sheath.

 

Fibre type

The TBU LSZH* SP1724 cable is available with multimode and singlemode fibres.

 

Technical performances

The tight buffer cable performances are specified in the following tables.

 

Additional details

This cable is provided as a standard with a black sheath, other sheath colours are also available. Long exposure to UV with these other colours could generate colour fading.

 

Euroclass

Dca S1 d0 a1

 

 

 

* LSZH: Low Smoke Zero Halogen.

 

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Strength member
Central FRP
Construction type
Multi Tight
Fiber optic type
OM3 50/125
Material used for longitudinal water tightness
Watertight glass yarns
Additional strength member
Glass yarn
Outer sheath
LSZH
Halogen free
IEC 60754-1
Metal free
Yes
Colour
Black

Dimensional characteristics

Dimensional characteristics

Cable Diameter, range
- mm
Number of optical fibres, range
-
Nominal outer diameter
5.3 mm
Approximate weight
33 kg/km
Number of optical fibres
6

Mechanical characteristics

Mechanical characteristics

Maximum installation tension
700 N
Maximum permanent tensile load
0.2 kN
Crush resistance (IEC 60794-1-E3)
100 N/cm
Mechanical resistance to impacts
10 impacts of 3 N.m

Usage characteristics

Usage characteristics

Flame retardant
IEC 60332-1
Fire retardant
IEC 60332-3
Smoke density
IEC 61034-2
U.V resistance
Very good
Water proof
Longitudinal & radial
Installation type
Indoor/Outdoor
Installation temperature, range
0 ... 40 °C
Storage temperature, range
-40 ... 70 °C
Operating temperature, range
-40 ... 70 °C
Minimum static operating bending radius
55 mm
Laying operation bending radius
85 mm

Resources

Resources

Selling & delivery Information

Standard Marking

Nexans - FIBRE OPTIC CABLE - TBU LSZH Dca s1 d1 a1 SP1724 - XXxYY - FB - TN - metric

XX = Fibre Count YY = Fibre Type FB = Frameries, Belgium (manufacturing place) TN = Traceability Number

Declaration of Performance

  • Declaration of Performance n� : 1001189-NOLA
  • Certification Date : 1/16/24
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 1000253
  • Declared performance : Dca-s1,d1,a1

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close