G12-9 QXWE D7,0 (FRP)

Description

Description

Standards

  • Product
    EN 187000; EN 187100; EN 187102; EN 188000; EN 188100; IEC 60794
  • Test
    IEC 60793
  • International
    ITU-T Rec. G.650; ITU-T Rec. G.652

The cable type is intended for outdoor use in aerial installations. The design can incorporate 12 to 192 fibres in loose tubes. The individually coloured fibres are tubed in groups of maximum 12, and stranded onto a central dielectric fibre reinforced strength member (FRP). The cable type is longitudinal water-blocked through the use of water-swellable materials. The cable core and the suspension strand are sheathed together with halogen-free black polyethylene in a figure eight section.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Construction type
Loose Tube
Fiber optic type
SM (G.652D)
Type of secondary protection
Loose tube
Outer sheath
PE
Sheath colour
Black
Material used for longitudinal water tightness
Swellable tape
Halogen free
Yes
Metal free
Yes
Suspension wire
Embedded FRP

Dimensional characteristics

Dimensional characteristics

Number of optical fibres, range
12 ... 192
Number of optical fibres
12
Wire diameter
7.0 mm
Total number of wires
1
Diameter over suspension strand
10.0 mm
Average sheath thickness
1.5 mm
Diameter over assembly
9.1 mm
Nominal outer diameter
12.1 mm
Approximate weight
235 kg/km
Height
25.1 mm

Mechanical characteristics

Mechanical characteristics

Maximum pulling force by laying
12 kN
Maximum permanent tensile load
9 kN
Crush resistance (EN 187 000)
3 kN
Impact resistance (EN 187 000)
15 J

Usage characteristics

Usage characteristics

Installation type
Aerial Cable
Minimum dynamic operating bending radius
350.0 mm
Operating temperature, range
-40 ... 70 °C
Ambient installation temperature, range
-15 ... 60 °C
Storage temperature, range
-40 ... 70 °C
Flame retardant
No
Minimum static operating bending radius
- mm

Resources

Resources

Selling & delivery Information

The outer sheath of the cable is marked with cable type, manufacturer, identification number and meter marking.
The cable is delivered on wooden recyclable drums in lengths according to arrangement. The drum is marked with the cable type, length, rolling direction and installation information. Cable ends closed with end cap.

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close