TKXP/2R 700/17

Description

Description

Standards

  • Product
    IEC 60800
  • Test
    EN 50265; IEC 60332-1

The TKXP/2R heating cable units are ideal comfort heating in concrete floor constructions. They are also ideal for storage heating and snow melting installations, for frost protection of roof gutters and drains, and soil heating.

Each unit has a unique factory made integrated splice which is marked =>SPLICE<= on the cable surface.

The factory made end seal is 100% waterproof. The cold lead is marked with ****** on the outer sheath.

The length of the cold lead is 2.3 m.

 

IP-class, end seal: IPX7

Minimum installation temperature (without any precautions) 0 °C.

Mechanical class: M2

UV-resistant: Yes

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Number of conductors
2
Type of conductor
Solid, Class 1
Insulation
XLPE (chemical)
Drain wire
Bare copper
Screen
Lead
Outer sheath
PVC
Sheath colour
Blue
Type of splice
Intergrated/hidden

Dimensional characteristics

Dimensional characteristics

Approximate net weight
7.4 kg
Nominal outer diameter
- mm
Height
6 mm
Width
8.5 mm

Electrical characteristics

Electrical characteristics

Nominal output
700 W
Nominal element resistance
75.6 Ohm
Max. element resistance
83.2 Ohm
Min. element resistance
71.8 Ohm
Operating voltage
230 V
Rated Voltage Uo/U
300/500 V

Usage characteristics

Usage characteristics

Element length
41 m
Bending factor when laying
5 (xD)
Flame retardant
IEC 60332-1
Length of cold lead
2.3 m
Max. temperature energized, outer sheath
65 °C
Output
17 W/m

Resources

Resources

Declaration of Performance

  • Declaration of Performance n� : 1000137-NOLA
  • Certification Date : 1/18/17
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 0402
  • Declared performance : Eca

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close