XTREME 840/17 YELLOW

Description

Description

Standards

  • International
    EN 50265; IEC 60332-1; IEC 60800

The XTREME heating cable units are ideal for comfort heating in concrete floor constructions, and especially where water/moisture may be present.

These units have cold leads in both ends of the cable, and each unit has two unique factory made integrated splices which are marked =>SPLICE<= on the cable surface. Thus these cables do not have any weak parts which would be installed in the floor, and all connections on the cable should be made outside the floor, i.e. in a junction box or similar.

 

The cold leads are marked with ****** on the outer sheath.

The length of each cold lead is approx. 2.3m.

Minimum installation temperature (without any precautions) 0 °C.

Mechanical class: M2

UV-resistant: Yes

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Number of conductors
2
Type of conductor
Solid, Class 1
Insulation
XLPE (chemical)
Drain wire
Bare copper
Screen
Lead
Outer sheath
PVC
Sheath colour
Yellow
Type of splice
Intergrated/hidden

Dimensional characteristics

Dimensional characteristics

Approximate net weight
9.0 kg
Height
6 mm
Nominal outer diameter
8.5 mm
Width
8.5 mm

Electrical characteristics

Electrical characteristics

Nominal output
840 W
Nominal element resistance
63 Ohm
Max. element resistance
69.3 Ohm
Min. element resistance
59.9 Ohm
Operating voltage
230 V

Usage characteristics

Usage characteristics

Element length
49.7 m
Bending factor when laying
5 (xD)
Flame retardant
IEC 60332-1
Length of cold lead
2.25 m
Max. temperature energized, outer sheath
65 °C
Output
17 W/m

Resources

Resources

Declaration of Performance

  • Declaration of Performance n� : 1000061-NOLA
  • Certification Date : 1/23/17
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 0402
  • Declared performance : Eca

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close