FLAMEX® 4GKW

Products

FLAMEX 4GKW 1.8/3kV 1x1

Nexans ref. 79461220

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1 mm²
  • Minimum outer diameter: 2.7 mm
  • Maximum outer diameter: 2.9 mm
  • Approximate weight: 16 kg/km

 

FLAMEX 4GKW 1.8/3kV 1x1.5

Nexans ref. 79461320

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Minimum outer diameter: 3.1 mm
  • Maximum outer diameter: 3.3 mm
  • Approximate weight: 21 kg/km

 

FLAMEX 4GKW 1.8/3kV 1x2.5

Nexans ref. 79461420

  • Packaging: Cut to length (m)
  • Conductor cross-section: 2.5 mm²
  • Minimum outer diameter: 3.55 mm
  • Maximum outer diameter: 3.85 mm
  • Approximate weight: 32 kg/km

 

FLAMEX 4GKW 1.8/3kV 1x4

Nexans ref. 79461520

  • Packaging: Cut to length (m)
  • Conductor cross-section: 4 mm²
  • Minimum outer diameter: 4.35 mm
  • Maximum outer diameter: 4.65 mm
  • Approximate weight: 48 kg/km

 

FLAMEX 4GKW 1.8/3kV 1x6

Nexans ref. 79461620

  • Packaging: Cut to length (m)
  • Conductor cross-section: 6 mm²
  • Minimum outer diameter: 4.95 mm
  • Maximum outer diameter: 5.25 mm
  • Approximate weight: 66 kg/km

 

FLAMEX 4GKW 1.8/3kV 1x10

Nexans ref. 79461720

  • Packaging: Cut to length (m)
  • Conductor cross-section: 10 mm²
  • Minimum outer diameter: 6.1 mm
  • Maximum outer diameter: 6.5 mm
  • Approximate weight: 110 kg/km

 

FLAMEX 4GKW 1.8/3kV 1x16

Nexans ref. 79461820

  • Packaging: Cut to length (m)
  • Conductor cross-section: 16 mm²
  • Minimum outer diameter: 8.1 mm
  • Maximum outer diameter: 8.5 mm
  • Approximate weight: 190 kg/km

 

Description

Description

Standards

  • International
    EN 45545-2 (HL3); EN 50264-3-1; IEC 60228

FLAMEX® 4GKW power cables are used for fixed and protected installations. This product range is recommended for narrow spaces where an optimal bending radius is required. FLAMEX® cables are designed to withstand tough working conditions (oil, ozone, temperature variation, etc.). 120°C conductor temperature is allowed for a 20,000 hours cumulative working time.

 

DESIGN

1. Conductor 

    Flexible stranded tinned copper, class 5 acc. to IEC 60228
Optional halogen-free separator tape

 

2. Insulation

    Cross-linked compound type EI 109 acc. to EN 50264-1
Oil, diesel, ozone and UV resistant
Colour: black

 

Example of cable marking up to 10 mm²: FLAMEX type EN 50264-3-1 1800V (mm²) M 4GKW I NEXANS I WW-YYYY
Example of cable marking from 16 mm²: FLAMEX EN 50264-3-1 1800V (mm²) M I NEXANS I WW-YYYY

 

FIRE SAFETY

FLAMEX® 4GKW power cables are conform to EN 45545-2 HL3

 

GUIDE TO USE

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: 3 x outer cable diameter (5 x D if D > 10mm)
    • For installation and occasional movements: 6 x outer cable diameter

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Tinned copper
Conductor flexibility
Flexible stranded
Insulation
Cross-linked compound
Halogen free
EN 50267-2-1 & EN 60684-2

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
1.8 / 3 (3.6) kV

Usage characteristics

Usage characteristics

Flame retardant
EN 60332-1-2
Fire retardant
EN IEC 60332-3-24 (cat C); EN IEC 60332-3-25 (EN50305)
Smoke density
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Operating temperature, range
-40 ... 90 °C
Chemical resistance
Good
Ozone resistance
Yes
U.V resistance
Yes

Resources

Resources

Documentation

xls — 0 B
xls — 0 B

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close