UX 0.6/1kV [P108]

Products

0.6/1kV UX [P108] NEW

Nexans ref. 10226222 - Country ref. 1027400

  • Packaging: Drum (m)
  • Conductor cross-section: 1 mm²
  • Nominal outer diameter: 5.3 mm
  • Approximate weight: 45 kg/km

 

0.6/1kV UX [P108] NEW

Nexans ref. 10226223 - Country ref. 1027401

  • Packaging: Drum (m)
  • Conductor cross-section: 1.5 mm²
  • Nominal outer diameter: 5.6 mm
  • Approximate weight: 55 kg/km

 

0.6/1kV UX [P108] NEW

Nexans ref. 10226264 - Country ref. 1027402

  • Packaging: Drum (m)
  • Conductor cross-section: 2.5 mm²
  • Nominal outer diameter: 6.0 mm
  • Approximate weight: 65 kg/km

 

0.6/1kV UX [P108] NEW

Nexans ref. 10226265 - Country ref. 1027403

  • Packaging: Drum (m)
  • Conductor cross-section: 4 mm²
  • Nominal outer diameter: 6.5 mm
  • Approximate weight: 85 kg/km

 

0.6/1kV UX [P108] NEW

Nexans ref. 10226266 - Country ref. 1027404

  • Packaging: Drum (m)
  • Conductor cross-section: 6 mm²
  • Nominal outer diameter: 7.1 mm
  • Approximate weight: 105 kg/km

 

0.6/1kV UX [P108] NEW

Nexans ref. 10226267 - Country ref. 1027405

  • Packaging: Drum (m)
  • Conductor cross-section: 10 mm²
  • Nominal outer diameter: 8.0 mm
  • Approximate weight: 150 kg/km

 

0.6/1kV UX [P108] NEW

Nexans ref. 10226268 - Country ref. 1027406

  • Packaging: Drum (m)
  • Conductor cross-section: 16 mm²
  • Nominal outer diameter: 9.2 mm
  • Approximate weight: 220 kg/km

 

0.6/1kV UX [P108] NEW

Nexans ref. 10226269 - Country ref. 1027407

  • Packaging: Drum (m)
  • Conductor cross-section: 25 mm²
  • Nominal outer diameter: 10.9 mm
  • Approximate weight: 330 kg/km

 

0.6/1kV UX [P108] NEW

Nexans ref. 10226270 - Country ref. 1027408

  • Packaging: Drum (m)
  • Conductor cross-section: 35 mm²
  • Nominal outer diameter: 12.2 mm
  • Approximate weight: 430 kg/km

 

0.6/1kV UX [P108] NEW

Nexans ref. 10226271 - Country ref. 1027409

  • Packaging: Drum (m)
  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 14.3 mm
  • Approximate weight: 585 kg/km

 

0.6/1kV UX [P108] NEW

Nexans ref. 10226272 - Country ref. 1027410

  • Packaging: Drum (m)
  • Conductor cross-section: 70 mm²
  • Nominal outer diameter: 16.0 mm
  • Approximate weight: 790 kg/km

 

0.6/1kV UX [P108] NEW

Nexans ref. 10226273 - Country ref. 1027411

  • Packaging: Drum (m)
  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 18.4 mm
  • Approximate weight: 1065 kg/km

 

0.6/1kV UX [P108] NEW

Nexans ref. 10226274 - Country ref. 1027412

  • Packaging: Drum (m)
  • Conductor cross-section: 120 mm²
  • Nominal outer diameter: 20.3 mm
  • Approximate weight: 1340 kg/km

 

0.6/1kV UX [P108] NEW

Nexans ref. 10226275 - Country ref. 1027413

  • Packaging: Drum (m)
  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 22.5 mm
  • Approximate weight: 1650 kg/km

 

0.6/1kV UX [P108] NEW

Nexans ref. 10226276 - Country ref. 1027414

  • Packaging: Drum (m)
  • Conductor cross-section: 185 mm²
  • Nominal outer diameter: 24.7 mm
  • Approximate weight: 2000 kg/km

 

0.6/1kV UX [P108] NEW

Nexans ref. 10226277 - Country ref. 1027415

  • Packaging: Drum (m)
  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 28.2 mm
  • Approximate weight: 2650 kg/km

 

0.6/1kV UX [P108] NEW

Nexans ref. 10226278 - Country ref. 1027416

  • Packaging: Drum (m)
  • Conductor cross-section: 300 mm²
  • Nominal outer diameter: 30.9 mm
  • Approximate weight: 3215 kg/km

 

Description

Description

Standards

  • International
    IEC 60092-353; IEC 60092-360; IEC 60332-3 Cat.A; IEC 60684-2; IEC 60754-1; IEC 60754-2; IEC 61034
  • National
    CSA C22.2 N° 03-01; NEK 606; UL 1581

Construction Details
  - Conductor : Circular tinned stranded copper as per IEC 60228, Class 2
  - Outer sheath :  Halogen free thermosetting compound as per IEC 60092-360, SHF2 or SHF2 Oil & Mud

Standard Applied
  - Design guideline : IEC 60092-353 & NEK 606-2016
  - Material
    Sheath : SHF2, IEC 60092-360
  - Flame retardant : IEC 60332-3-22, Cat.A
  - Halogen free properties : IEC 60754-1,2 & IEC 60684-2
  - Low smoke properties : IEC 61034-1,2
  - Sunlight resistance : UL 1581
  - Cold properties (option) : CSA C22.2 No.03 (Bending : -40C, Impact : -35C)
  - Oil/Mud resistance (option) : NEK 606-2016 (Category a, b, c, d)

Identification of color
  - Insulation : Green/Yellow stripe
    Note) Any other colors purchaser required

 

Type approval
 - ABS, BV, DNV, LR

Marking
 NEXANS KUKDONG UX P108 0.6/1KV 1Cx25 SQMM IEC 60332-3 A year length

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Tinned annealed copper
Conductor shape
Circular stranded (RM)
Outer sheath
Polyolefin SHF2

Dimensional characteristics

Dimensional characteristics

Number of cores
1

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV

Usage characteristics

Usage characteristics

Flame retardant
IEC 60332-3 Cat. A
Weather resistance
Yes
Chemical resistance
Good
Smoke density
IEC 61034
Gases corrosivity
IEC 60754-1; IEC 60754-2
Mud resistance
NEK606
Oil resistance
Yes
Standard
NEK

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close