FEVE 1,8/3kV 3x95+2x1,5+G12

Description

Description

Standards

  • Product
    IEC 60228; IEC 60502; Nexans specification

WATERLINK FEVE 1.8 / 3kV is a submarine cable construction, specifically designed for aquaculture and fish farms, for the harsh and varying weather conditions in Norway. The cable is manufactured to withstand the harsh conditions it may be exposed to both during installation and operation.

 

WATERLINK FEVE 1.8 / 3kV is a grease filled, double armored, submarine cable construction, with single mode fiber optics included in the cable. The cable is mainly used as power supply cable between shore/land and fish farm or aquaculture units at sea, but is also approved for other submarine cable systems. The cable armoring consists of galvanized steel wires which meet the requirements of NEK 400 Fish farms. The cable is designed for use in all classes defined in NEK 9415 (Floating aquaculture).
It is recommended that the maximum voltage drop along the cable don`t exceed approximately 4%, to be in accordance with NEK 400-5-525.

 

OPTIONS

WATER LINK FEVE 1.8 / 3kV normally supplied with a fiber element G12x9 / 125 single mode. This can either be removed or modified to a multimode fibre as desired. It is how ever recommended that single mode is used, due to the restrictions for multimode at long lengths. It is also possible to include control or signal pairs.

 

Option 4

1x8mm2 control conductor isolation monitoring.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Armour type
Galvanised round steel wires
Colour
Black
Conductor flexibility
Stranded class 2
Conductor material
Annealed copper
Fiber optic type
SingleMode 9/125
Halogen free
Yes
Inner sheath
Polyethylene
Insulation
PE
Outer sheath
PE
Sheath colour
Black
Type of conductor
Circular, stranded, class 2
With Green/Yellow core
No

Dimensional characteristics

Dimensional characteristics

Nominal outer diameter
46.1 mm
Approximate net weight
6200 kg/km
Approximate weight
- kg/km
Approximate weight in seawater
4500 kg/km
Armour thickness
2 mm
Conductor cross-section
- mm²
Conductor diameter
- mm
Number of cores
3

Electrical characteristics

Electrical characteristics

Permissible current rating in open air
285 A
Permissible current rating submerged in water, 15°C ambient temperature
315 A
Permissible current rating when buried
290 A
Rated Voltage Uo/U (Um)
1.8 / 3 (3.6) kV

Usage characteristics

Usage characteristics

Operating temperature, range
-25 ... 50 °C
Bending factor when laying
- (xD)
Category
Laying operation bending radius
900 mm
Maximum deployment ocean depth
500 m

Resources

Resources

Documentation

xlsx — 0 B

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close