10 par 0,6 PTS HF B2 90

Description

Description

Standards

  • International
    IEC 60332-1; IEC 60754; IEC 61034

CONSTRUCTION

1. Conductors

Single tinned annealed cooper wire, diameter of 0,6 mm.

2. Insulation

Coloured PE, nom. average thickness is 0,20 mm.

3. Twisting

Insulated conductors twisted in to the pairs.

4. Built-up

PE insulated Cu wire, twisted conductors in a pair, cables with more then 5 pairs are banded with PETP foil, halogen free sheath type HFFR-LS.

5. Screen

Lengthwise Al/PETP tape, beneath the tape, there is one lengthwise tinned drain wire 0,5 mm.

QUALITY AND ENVIRONMENTAL SYSTEM

Construction, production and testing are made according to ISO 9001 and 14001.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Type of conductor
Circular, solid
Conductor material
Tinned copper
Insulation
PE
Lay Up
Pairs
Twisted
Yes
Material of bedding
PETP-foil
Screen
Aluminium-Polyester tape
Outer sheath
LSZH-FR
Halogen free
-
Sheath colour
White
Conductor flexibility
Solid

Dimensional characteristics

Dimensional characteristics

Number of pairs
10
Nominal outer diameter
8.7 mm
Approximate weight
95 kg/km
Average insulation thickness
0.2 mm
Average sheath thickness
0.75 mm
Conductor diameter
0.6 mm
Copper content
54.6 kg/km

Electrical characteristics

Electrical characteristics

Capacitance unbalance pair to pair
990 pF/km
Max. DC resistance of the conductor at 20°C
65 Ohm/km
Max. capacity pair / core to core
75 nF/km
Nominal resistance of the conductor
61.00 Ohm/km
Ohmical resistance of the insulation
500 MOhm.km

Usage characteristics

Usage characteristics

Length
90 m
Ambient installation temperature, range
-10 ... 40 °C
Laying operation bending radius
61 mm
Operating temperature, range
-15 ... 70 °C

Resources

Resources

Documentation

Farveskema pdf — 34.3 kB

Declaration of Performance

  • Declaration of Performance n� : 1000242-NOLA
  • Certification Date : 6/9/17
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : NB0366
  • Declared performance : Dca-s2,d2,a2

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.