F50-0.5 EXLI-60P

Description

Description

Standards

  • International
    IEC 60332-1

The cable consists of plain, annealed copper conductors bundled in twisted pairs. Conductor dimensions are 0.4 and 0.5 mm. Cables with more than 10 pairs have sub-units of 10 pairs, and cables with 100 pairs or more have main units of 50 pairs.

 

PE-insulated, pair-twisted, screened telecommunicationcable with halogen free, flame retardant sheath. The core is wrapped with polyester tape and a longitudinal screen of one layer of aluminium/polyester tape. The cable is unfilled. The outer sheath is a light green halogen-free, flame retardant polymer. The outer sheath is bonded to the screen. Fire performance according to CPR class Dcas2d2a2.

 

Information on electrical data, as well as cable core design and identification, is attached in the section on Related Information.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Type of conductor
Circular, solid
Conductor material
Copper
Insulation
PE
Lay Up
Pairs
Twisted
Yes
Screen
Aluminium-Polyester tape + tinned copper drain wire
Outer sheath
HFFR (polyolefin)
Sheath colour
Green
Conductor flexibility
Solid

Dimensional characteristics

Dimensional characteristics

Conductor diameter
0.5 mm
Number of pairs
50
Nominal outer diameter
15.8 mm
Approximate weight
350 kg/km

Mechanical characteristics

Mechanical characteristics

Minimum breaking load
4 kN
Maximum pulling force by laying
2 kN
Maximum tensile load during service (Tl)
100.0 daN

Usage characteristics

Usage characteristics

Length
250 m
Minimum static operating bending radius
120 mm
Operating temperature, range
-40 ... 60 °C
Ambient installation temperature, range
-15 ... 40 °C
Storage temperature, range
-40 ... 70 °C

Resources

Resources

Documentation

Selling & delivery Information

Delivery length: 250 m on drum

Declaration of Performance

  • Declaration of Performance n� : 1000826-SEGR
  • Certification Date : 4/4/19
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 0366
  • Declared performance : Dca-s2,d2,a2

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close