TXXI-O Inntak 0,6/1 kV 4G95 mm² AFR

Description

Description

Standards

  • International
    HD 603.5J; IEC 60332-1-2

Power distribution cable, designated for road lights, entry point installation or other general outdoor use (UV-resistant).

The cable is fire-retardant and halogen free, each phase having insulation and an outer sheath.

Can be placed directly in soil.

When laying at a lower temperatures than 0 degrees Celsius, care must be taken to avoid damage to the outer sheath. It is especially important that the cable is not exposed to impact at temperatures below 0  °C.

When laying at lower temperatures than -10 degrees Celsius, the cable should be preheated before laying as well.

If the cable is cut and not installed immediately, each phase must be sealed, to prevent water intrusion.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum
Type of conductor
Circular compacted stranded
Insulation
XLPE (chemical)
With Green/Yellow core
Yes
Halogen free
Yes
Outer sheath
Halogen free, fire retardant
Conductor flexibility
Stranded class 2
Conductor shape
Round, stranded

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
95 mm²
Conductor diameter
11.4 mm
Number of cores
4
Diameter over insulation
13.6 mm
Nominal outer diameter
44.6 mm
Tube diameter
12 mm
Inner diameter
9 mm
Approximate weight
1.7 kg/m

Electrical characteristics

Electrical characteristics

Permissible current rating in open air
245 A
Permissible current rating when buried
260 A
Max. DC resistance of the conductor at 20°C
0.32 Ohm/km
Inductive reactance at 50Hz
0.086 Ohm/km
Nominal inductance
0.27 mH/km
Capacity of phase cores approx.
0.09 µF / km
Zero sequence reactance at 50HZ
0.36 Ohm/km
Zero sequence resistance at 20°C
1.28 Ohm/km
Permissible short circuit current conductor 1s
9 kA
Maximum operating voltage
1000 V
Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV

Mechanical characteristics

Mechanical characteristics

Maximum Pulling Tension
11.4 kN
Minimum repeated bending diameter
535 mm

Usage characteristics

Usage characteristics

Packaging
NX16
Length
450 m
Maximum operating temperature
90 °C
Short-circuit max. conductor temperature
250 °C
Minimum installation temperature
-15 °C
Bending factor when laying
6 (xD)
Flame retardant
IEC 60332-1-2
RoHS compliant
Yes

Resources

Resources

Declaration of Performance

  • Declaration of Performance n� : 1000974-NOLA
  • Certification Date : 1/26/21
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 0366
  • Declared performance : Dca-s2,d2,a2

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close