TSLF (HD) 24kV 3x1x400A
TSLF (HD) 24kV 3x1x400A
TSLF (HD) 24kV 3x1x240A
Read more- Nexans ref. : 10559234
- Country ref. : 1087823
- EAN : 7045210128642
Description
Description
Standards
-
ProductHD 620.10K
User benefits:
Diffusion free high voltage cable.
Avoids growth of watertrees in the XLPE insulation and increases the lifetime of the cable.
Sheath integrity may be tested while on drum, before backfilling, in plastic pipes etc.
Screen section: Value given is the physical cross section of the copper wires in the screen of one core.
Usage:
Indoor
Underground
Outdoors
Intended for high voltage energy distribution
Fire propertirs:
Halogen free
Cable marking:
NEXANS NS TSLF 12 kV 1 x mm²/mm² MONTH YEAR
Lifemark
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor material
Aluminum
Conductor shape
Circular compacted
Material used for longitudinal water tightness
Swelling powder
Material of the inner semi-conductor
Extruded
Insulation
XLPE (chemical)
Material of the external semi-conductor
Extruded
Screen
Copper wire
Armour type
Aluminium foil
Radial waterproof
Yes
Outer sheath
HDPE
Outer conductive layer
Yes
Halogen free
Yes
Conductor flexibility
Stranded class 2
Dimensional characteristics
Dimensional characteristics
Conductor cross-section
400 mm²
Conductor diameter
23.6 mm
Diameter over insulation
35.5 mm
Nominal insulation thickness
5.5 mm
Earth conductor cross section
35 mm²
Screen section
21 mm²
Average sheath thickness
2.6 mm
Nominal outer diameter
95.5 mm
Approximate weight
6.72 kg/m
Number of cores
3
Electrical characteristics
Electrical characteristics
Perm. current rating buried 15°C - trefoil formation
575 A
Perm. current rating in air 25°C - trefoil formation
705 A
Max. DC resistance of the conductor at 20°C
0.0778 Ohm/km
Permissible short circuit current conductor 1s
37.8 kA
Nominal phase capacitance
0.35 µF / km
Inductive reactance at 50Hz - trefoil
- Ohm/km
Phase reactance 50 Hz - trefoil formation
0.1 Ohm/km
A.C. Conductor resist. 50Hz and at 90 °C
- Ohm/km
Maximum operating voltage
24 kV
Rated Voltage Uo/U (Um)
12 / 20 (24) kV
Mechanical characteristics
Mechanical characteristics
Maximum Pulling Tension
36 kN
Minimum repeated bending diameter
955 mm
Usage characteristics
Usage characteristics
Packaging
NX24
Length
300 m
Maximum operating temperature
90 °C
Short-circuit max. conductor temperature
250 °C
Minimum installation temperature
-20 °C
Bending factor when laying
5 (xD)