TSLF-J 24 - 36kV single core with copper wire

Products

TSLF-J 24kV 1x50A KGF50

Nexans ref. 10581199 - Country ref. 1007990

  • Packaging: Drum (1000m)
  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 27.0 mm
  • Ground conductor cross-section: 50 mm²
  • Perm. current rating buried 15°C - flat formation: 200 A
  • Perm. current rating buried 15°C - trefoil formation: 180 A
  • Maximum operating voltage: 24 kV
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Maximum Pulling Tension: 1.5 kN

 

TSLF-J 24kV 1x95A KGF25

Nexans ref. 10224444 - Country ref. 1021213

  • Packaging: Drum (1000m)
  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 30.6 mm
  • Ground conductor cross-section: 25 mm²
  • Perm. current rating buried 15°C - flat formation: 290 A
  • Perm. current rating buried 15°C - trefoil formation: 265 A
  • Maximum operating voltage: 24 kV
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Maximum Pulling Tension: 2.85 kN

 

TSLF-J 24kV 1x95A KGF50

Nexans ref. 10224450 - Country ref. 1021219

  • Packaging: Drum (1000m)
  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 30.6 mm
  • Ground conductor cross-section: 50 mm²
  • Perm. current rating buried 15°C - flat formation: 290 A
  • Perm. current rating buried 15°C - trefoil formation: 265 A
  • Maximum operating voltage: 24 kV
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Maximum Pulling Tension: 2.85 kN

 

TSLF-J 36kV 1x150A KGF50

Nexans ref. 10266325

  • Packaging: Drum (1000m)
  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 39.9 mm
  • Ground conductor cross-section: 50 mm²
  • Perm. current rating buried 15°C - flat formation: 350 A
  • Perm. current rating buried 15°C - trefoil formation: 340 A
  • Maximum operating voltage: 36 kV
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV
  • Maximum Pulling Tension: 4.5 kN

 

TSLF-J 24kV 1x240A KGF25

Nexans ref. 10224446 - Country ref. 1021215

  • Packaging: Drum (1000m)
  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 38.1 mm
  • Ground conductor cross-section: 25 mm²
  • Perm. current rating buried 15°C - flat formation: 585 A
  • Perm. current rating buried 15°C - trefoil formation: 445 A
  • Maximum operating voltage: 24 kV
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Maximum Pulling Tension: 7.2 kN

 

TSLF-J 24kV 1x240A KGF50

Nexans ref. 10224452 - Country ref. 1021229

  • Packaging: Drum (1000m)
  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 38.1 mm
  • Ground conductor cross-section: 50 mm²
  • Perm. current rating buried 15°C - flat formation: 465 A
  • Perm. current rating buried 15°C - trefoil formation: 445 A
  • Maximum operating voltage: 24 kV
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Maximum Pulling Tension: 7.2 kN

 

TSLF-J 36kV 1x240A KGF50

Nexans ref. 10266327

  • Packaging: Drum (1000m)
  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 44.2 mm
  • Ground conductor cross-section: 50 mm²
  • Perm. current rating buried 15°C - flat formation: 450 A
  • Perm. current rating buried 15°C - trefoil formation: 450 A
  • Maximum operating voltage: 36 kV
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV
  • Maximum Pulling Tension: 7.2 kN

 

TSLF-J 24kV 1x400A KGF25

Nexans ref. 10224447 - Country ref. 1021216

  • Packaging: Drum (1000m)
  • Conductor cross-section: 400 mm²
  • Nominal outer diameter: 44.3 mm
  • Ground conductor cross-section: 25 mm²
  • Perm. current rating buried 15°C - flat formation: 585 A
  • Perm. current rating buried 15°C - trefoil formation: 575 A
  • Maximum operating voltage: 24 kV
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Maximum Pulling Tension: 12 kN

 

TSLF-J 24kV 1x400A KGF50

Nexans ref. 10224453 - Country ref. 1021236

  • Packaging: Drum (1000m)
  • Conductor cross-section: 400 mm²
  • Nominal outer diameter: 44.3 mm
  • Ground conductor cross-section: 50 mm²
  • Perm. current rating buried 15°C - flat formation: 585 A
  • Perm. current rating buried 15°C - trefoil formation: 575 A
  • Maximum operating voltage: 24 kV
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Maximum Pulling Tension: 12 kN

 

TSLF-J 36kV 1x400A KGF50

Nexans ref. 10266329

  • Packaging: Drum (1000m)
  • Conductor cross-section: 400 mm²
  • Nominal outer diameter: 50.4 mm
  • Ground conductor cross-section: 50 mm²
  • Perm. current rating buried 15°C - flat formation: 565 A
  • Perm. current rating buried 15°C - trefoil formation: 580 A
  • Maximum operating voltage: 36 kV
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV
  • Maximum Pulling Tension: 12 kN

 

TSLF-J 24kV 1x630A KGF25

Nexans ref. 10224448 - Country ref. 1021217

  • Packaging: Drum (1000m)
  • Conductor cross-section: 630 mm²
  • Nominal outer diameter: 50.1 mm
  • Ground conductor cross-section: 25 mm²
  • Perm. current rating buried 15°C - flat formation: 710 A
  • Perm. current rating buried 15°C - trefoil formation: 735 A
  • Maximum operating voltage: 24 kV
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Maximum Pulling Tension: 18.9 kN

 

TSLF-J 24kV 1x630A KGF50

Nexans ref. 10224454 - Country ref. 1021237

  • Packaging: Drum (1000m)
  • Conductor cross-section: 630 mm²
  • Nominal outer diameter: 50.1 mm
  • Ground conductor cross-section: 50 mm²
  • Perm. current rating buried 15°C - flat formation: 710 A
  • Perm. current rating buried 15°C - trefoil formation: 735 A
  • Maximum operating voltage: 24 kV
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Maximum Pulling Tension: 18.9 kN

 

TSLF-J 36kV 1x630A KGF50

Nexans ref. 10266331

  • Packaging: Drum (1000m)
  • Conductor cross-section: 630 mm²
  • Nominal outer diameter: 57.9 mm
  • Ground conductor cross-section: 50 mm²
  • Perm. current rating buried 15°C - flat formation: 675 A
  • Perm. current rating buried 15°C - trefoil formation: 740 A
  • Maximum operating voltage: 36 kV
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV
  • Maximum Pulling Tension: 18.9 kN

 

Description

Description

Standards

  • International
    HD 620.10K

User benefits:

Diffusion free high voltage cable. Avoids therefore growth of water trees in the XLPE insulation which increases the lifetime.

The semiconducting layer makes it easy to test the outer sheats integrity while on drum, before backfilling, in plastic tubes etc.

Screen section: Value given is the physical cross section of the copper wires in one core.

The cable has one groud wire attached to the oversheet.

Usage:

Indoor

Underground

Outdoors

Intended for high voltage energy distribution

Fire properties:

Halogen free

Cable marking:

NEXANS NS TSLF xx kV 1 x mm²/mm² MONTH YEAR

Lifemark

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Stranded class 2

Dimensional characteristics

Dimensional characteristics

Number of cores
1

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close