- Products
- Segments
- Newsroom
- Tools and Resources
- Sustainability
- We are Nexans
- Search
- Contact us
- Compare
- Sign in
TSLF-O 24 - 36kV MP single core with tube and red searchable marking stripe
TSLF-O 24 - 36kV MP single core with tube and red searchable marking stripe
Metal screened cable with laminated aluminium and outer semiconducting layer. A red searchable marking stripe and one optical tube is fastend to the cable surfase with a strong tape for future installation of optical cable.
Read moreTSLF-O 24kV 1x50A M
Nexans ref.
- Packaging: Drum (1000m)
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 27.0 mm
- Approximate weight: 0.765 kg/m
- Perm. current rating buried 15°C - flat formation: 200 A
- Maximum operating voltage: 24 kV
- Maximum Pulling Tension: 1.5 kN
TSLF-O 24kV 1x95A M
Nexans ref.
- Packaging: Drum (1000m)
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 30.6 mm
- Approximate weight: 1.034 kg/m
- Perm. current rating buried 15°C - flat formation: 290 A
- Maximum operating voltage: 24 kV
- Maximum Pulling Tension: 2.85 kN
TSLF-O 24kV 1x150A M
Nexans ref.
- Packaging: Drum (1000m)
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 33.7 mm
- Approximate weight: 1.271 kg/m
- Perm. current rating buried 15°C - flat formation: 365 A
- Maximum operating voltage: 24 kV
- Maximum Pulling Tension: 4.5 kN
TSLF-O 24kV 1x240A M
Nexans ref.
- Packaging: Drum (1000m)
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 38.1 mm
- Approximate weight: 1.721 kg/m
- Perm. current rating buried 15°C - flat formation: 465 A
- Maximum operating voltage: 24 kV
- Maximum Pulling Tension: 7.2 kN
TSLF-O 24kV 1x400A MP
Nexans ref. 10551185 - Country ref. 1087885
- Packaging: Drum (500m)
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 44.3 mm
- Approximate weight: 2.311 kg/m
- Perm. current rating buried 15°C - flat formation: 585 A
- Maximum operating voltage: 24 kV
- Maximum Pulling Tension: 12 kN
TSLF-O 24kV 1x630A M
Nexans ref.
- Packaging: Drum (500m)
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 51.0 mm
- Approximate weight: 3.251 kg/m
- Perm. current rating buried 15°C - flat formation: 710 A
- Maximum operating voltage: 24 kV
- Maximum Pulling Tension: 18.9 kN
TSLF-O 36kV 1x 95A M
Nexans ref.
- Packaging: Drum (1000m)
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 36.8 mm
- Approximate weight: 1.34 kg/m
- Perm. current rating buried 15°C - flat formation: 295 A
- Maximum operating voltage: 36 kV
- Maximum Pulling Tension: 2.85 kN
TSLF-O 36kV 1x150A M
Nexans ref.
- Packaging: Drum (1000m)
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 39.9 mm
- Approximate weight: 1.694 kg/m
- Perm. current rating buried 15°C - flat formation: 350 A
- Maximum operating voltage: 36 kV
- Maximum Pulling Tension: 4.5 kN
TSLF-O 36kV 1x240A M
Nexans ref.
- Packaging: Drum (1000m)
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 44.2 mm
- Approximate weight: 2.084 kg/m
- Perm. current rating buried 15°C - flat formation: 450 A
- Maximum operating voltage: 36 kV
- Maximum Pulling Tension: 7.2 kN
TSLF-O 36kV 1x400A M
Nexans ref.
- Packaging: Drum (500m)
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 50.4 mm
- Approximate weight: 2.69 kg/m
- Perm. current rating buried 15°C - flat formation: 565 A
- Maximum operating voltage: 36 kV
- Maximum Pulling Tension: 12 kN
TSLF-O 36kV 1x630A M
Nexans ref.
- Packaging: Drum (500m)
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 57.9 mm
- Approximate weight: 3.8 kg/m
- Perm. current rating buried 15°C - flat formation: 675 A
- Maximum operating voltage: 36 kV
- Maximum Pulling Tension: 18.9 kN
Description
Description
Standards
-
ProductHD 620.10K
User benefits:
Diffusion free high voltage cable. Avoids therefore growth of water trees in the XLPE insulation which increases the lifetime.
The semiconducting layer makes it easy to test the outer sheats integrity while on drum, before backfilling, in plastic tubes etc.
Screen section: Value given is the physical cross section of the copper wires in one core.
The cable has three tubes for future installation of optical cables.
Usage:
Indoor
Underground
Outdoors
Intended for high voltage energy distribution
Fire properties:
Halogen free
Cable marking:
NEXANS NS TSLF XX kV 1 x mm²/mm² MONTH YEAR
Lifemark
Characteristics
Characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania