TSLF-O 24 - 36kV MP single core with tube and red searchable marking stripe

Products

TSLF-O 24kV 1x50A M

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 27.0 mm
  • Approximate weight: 0.765 kg/m
  • Perm. current rating buried 15°C - flat formation: 200 A
  • Maximum operating voltage: 24 kV
  • Maximum Pulling Tension: 1.5 kN

 

TSLF-O 24kV 1x95A M

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 30.6 mm
  • Approximate weight: 1.034 kg/m
  • Perm. current rating buried 15°C - flat formation: 290 A
  • Maximum operating voltage: 24 kV
  • Maximum Pulling Tension: 2.85 kN

 

TSLF-O 24kV 1x150A M

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 33.7 mm
  • Approximate weight: 1.271 kg/m
  • Perm. current rating buried 15°C - flat formation: 365 A
  • Maximum operating voltage: 24 kV
  • Maximum Pulling Tension: 4.5 kN

 

TSLF-O 24kV 1x240A M

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 38.1 mm
  • Approximate weight: 1.721 kg/m
  • Perm. current rating buried 15°C - flat formation: 465 A
  • Maximum operating voltage: 24 kV
  • Maximum Pulling Tension: 7.2 kN

 

TSLF-O 24kV 1x400A MP

Nexans ref. 10551185 - Country ref. 1087885

  • Packaging: Drum (500m)
  • Conductor cross-section: 400 mm²
  • Nominal outer diameter: 44.3 mm
  • Approximate weight: 2.311 kg/m
  • Perm. current rating buried 15°C - flat formation: 585 A
  • Maximum operating voltage: 24 kV
  • Maximum Pulling Tension: 12 kN

 

TSLF-O 24kV 1x630A M

Nexans ref.

  • Packaging: Drum (500m)
  • Conductor cross-section: 630 mm²
  • Nominal outer diameter: 51.0 mm
  • Approximate weight: 3.251 kg/m
  • Perm. current rating buried 15°C - flat formation: 710 A
  • Maximum operating voltage: 24 kV
  • Maximum Pulling Tension: 18.9 kN

 

TSLF-O 36kV 1x 95A M

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 36.8 mm
  • Approximate weight: 1.34 kg/m
  • Perm. current rating buried 15°C - flat formation: 295 A
  • Maximum operating voltage: 36 kV
  • Maximum Pulling Tension: 2.85 kN

 

TSLF-O 36kV 1x150A M

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 39.9 mm
  • Approximate weight: 1.694 kg/m
  • Perm. current rating buried 15°C - flat formation: 350 A
  • Maximum operating voltage: 36 kV
  • Maximum Pulling Tension: 4.5 kN

 

TSLF-O 36kV 1x240A M

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 44.2 mm
  • Approximate weight: 2.084 kg/m
  • Perm. current rating buried 15°C - flat formation: 450 A
  • Maximum operating voltage: 36 kV
  • Maximum Pulling Tension: 7.2 kN

 

TSLF-O 36kV 1x400A M

Nexans ref.

  • Packaging: Drum (500m)
  • Conductor cross-section: 400 mm²
  • Nominal outer diameter: 50.4 mm
  • Approximate weight: 2.69 kg/m
  • Perm. current rating buried 15°C - flat formation: 565 A
  • Maximum operating voltage: 36 kV
  • Maximum Pulling Tension: 12 kN

 

TSLF-O 36kV 1x630A M

Nexans ref.

  • Packaging: Drum (500m)
  • Conductor cross-section: 630 mm²
  • Nominal outer diameter: 57.9 mm
  • Approximate weight: 3.8 kg/m
  • Perm. current rating buried 15°C - flat formation: 675 A
  • Maximum operating voltage: 36 kV
  • Maximum Pulling Tension: 18.9 kN

 

Description

Description

Standards

  • Product
    HD 620.10K

User benefits:

Diffusion free high voltage cable. Avoids therefore growth of water trees in the XLPE insulation which increases the lifetime.

The semiconducting layer makes it easy to test the outer sheats integrity while on drum, before backfilling, in plastic tubes etc.

Screen section: Value given is the physical cross section of the copper wires in one core.

 

The cable has three tubes for future installation of optical cables.

Usage:

Indoor

Underground

Outdoors

Intended for high voltage energy distribution

Fire properties:

Halogen free

Cable marking:

NEXANS NS TSLF XX kV 1 x mm²/mm² MONTH YEAR

Lifemark

Characteristics

Characteristics

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close