- Products
- Segments
- Newsroom
- Tools and Resources
- Sustainability
- We are Nexans
- Search
- Contact us
- Compare
- Sign in
TSLI 24kV 3x1x240A
TSLI 24kV 3x1x240A
Metal screened cable with laminated aluminium and polyethylene sheath. Tree twisted cores.
Read more- Nexans ref. : 10251790
- Country ref. : 1017533
- EAN : 7045210076226
Description
Description
Standards
-
ProductHD 620.10K; IEC 60228; IEC 60502-2
-
TestIEC 60332-3 Cat.C
User benefits:
Diffusion free high voltage cable.
Avoids therefore growth of water trees in the XLPE insulation which increases the lifetime
Usage:
Indoor
Tunnels
Industrial installations
Outdoors
Intended for high voltage energy distribution
Fire propertirs:
Fire retardent
Halogen free
Cable marking:
NEXANS NS TSLI XX kV 1 x mm²/mm² MONTH YEAR
Lifemark
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor material
Aluminum
Conductor shape
Circular compacted
Material used for longitudinal water tightness
Swelling powder
Material of the inner semi-conductor
Extruded
Insulation
Extruded XLPE compound
Material of the external semi-conductor
Extruded
Screen
Copper wire
Armour type
Aluminium foil
Radial waterproof
Yes
Individual sheath
Outer sheath
Fire-retardant
Halogen free
Yes
Conductor flexibility
Stranded class 2
Dimensional characteristics
Dimensional characteristics
Average insulation thickness
5.5 mm
Conductor cross-section
240 mm²
Conductor diameter
18.2 mm
Diameter over insulation
29.5 mm
Nominal insulation thickness
5.5 mm
Earth conductor cross section
35 mm²
Screen section
21 mm²
Average sheath thickness
2.5 mm
Nominal outer diameter
82.1 mm
Approximate weight
4.95 kg/m
Approximate weight
5075 kg/km
Number of cores
3
Electrical characteristics
Electrical characteristics
Perm. current rating buried 15°C - trefoil formation
445 A
Perm. current rating in air 25°C - trefoil formation
525 A
Max. DC resistance of the conductor at 20°C
0.125 Ohm/km
Permissible short circuit current conductor 1s
21.6 kA
Nominal phase capacitance
0.28 µF / km
Phase reactance 50 Hz - trefoil formation
0.11 Ohm/km
Permissible short circuit current
21600 A
Maximum operating voltage
24 kV
Rated Voltage Uo/U (Um)
12 / 20 (24) kV
Mechanical characteristics
Mechanical characteristics
Maximum Pulling Tension
21.6 kN
Minimum repeated bending diameter
821 mm
Usage characteristics
Usage characteristics
Maximum operating temperature
90 °C
Short-circuit max. conductor temperature
250 °C
Minimum installation temperature
-20 °C
Bending factor when laying
5 (xD)
Resources
Resources
Declaration of Performance
- Declaration of Performance n� : 1000997-NOLA
- Certification Date : 3/10/21
- AVCP (Assessment and Verification of Constancy of Performance) : System 3
- Notified body : NB 0081
- Declared performance : Dca-s2,d2,a2
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania