TSLI 170 kV 1x400A/50

Description

Description

Standards

  • Test
    IEC 60840

User benefits:

Diffusion free high voltage cable

Avoids growth of watertrees in the XLPE insulation and increases the lifetime of the cable.

Sheath integrity may be tested while on drum, before backfilling, in plastic pipes etc.

Meter marks

Screen section: Value given is the physical cross section of the copper wires in the screen.

Usage: Indoor,Tunnels, Industrial installations, Underground, Outdoors

Intended for high voltage energy distribution where a fire retardent cable is required.

Fire properties:

Halogenfree and fire retardent

Cable marking:

NEXANS NS TSLF  kV 1 x mm²/mm² MONTH YEAR, metermarks

Lifemark

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum
Conductor shape
Circular compacted
Material used for longitudinal water tightness
Swelling powder
Material of the inner semi-conductor
Extruded
Insulation
Extruded XLPE compound
Material of the external semi-conductor
Extruded
Screen
Copper wire
Radial waterproof
Yes
Outer sheath
HFFR (Halogen Free Flame Retardant)
Halogen free
Yes
Conductor flexibility
Stranded class 2

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
400 mm²
Conductor diameter
23.2 mm
Nominal insulation thickness
18.0 mm
Diameter over insulation
62.8 mm
Earth conductor cross section
- mm²
Screen section
50 mm²
Average sheath thickness
3.5 mm
Nominal outer diameter
75.8 mm
Approximate weight
5.56 kg/m
Number of cores
1

Electrical characteristics

Electrical characteristics

Max. DC resistance of the conductor at 20°C
0.0778 Ohm/km
Phase reactance 50 Hz - trefoil formation
0.13 Ohm/km
Phase reactance 50 Hz - flat formation
0.17 Ohm/km
Maximum operating voltage
170 kV
Perm. current rating buried 15°C - flat formation
530 A
Perm. current rating buried 15°C - trefoil formation
565 A
Perm. current rating in air 25°C - flat formation
700 A
Perm. current rating in air 25°C - trefoil formation
685 A
Permissible short circuit current conductor 1s
36 kA
Nominal phase capacitance
0.15 µF / km
Rated Voltage Uo/U (Um)
87/150 (170) kV

Mechanical characteristics

Mechanical characteristics

Maximum Pulling Tension
12 kN
Minimum repeated bending diameter
1520 mm

Usage characteristics

Usage characteristics

Maximum operating temperature
90 °C
Short-circuit max. conductor temperature
250 °C
Minimum installation temperature
-20 °C
Bending factor when laying
10 (xD)

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close