MILLICABLE 230V, twin conductor heating cable 6 W/m

Products

MILLICABLE 120/6

Nexans ref. 10127990 - Country ref. 1034219

  • Packaging: Box (Unit)
  • Type of splice: Moulded
  • Nominal output: 120 W
  • Nominal element resistance: 440.8 Ohm
  • Element length: 20 m

 

MILLICABLE 180/6

Nexans ref. 10196901 - Country ref. 1036512

  • Packaging: Box (Unit)
  • Type of splice: Moulded
  • Nominal output: 180 W
  • Nominal element resistance: 293.9 Ohm
  • Element length: 30 m

 

MILLICABLE/2 235/6 (HS)

Nexans ref. 10264858 - Country ref. 1034230

  • Packaging: Box (Unit)
  • Type of splice: Intergrated/hidden
  • Nominal output: 235 W
  • Nominal element resistance: 226.5 Ohm
  • Element length: 40 m

 

MILLICABLE/2 290/6 (HS)

Nexans ref. 10264859 - Country ref. 1034232

  • Packaging: Box (Unit)
  • Type of splice: Intergrated/hidden
  • Nominal output: 290 W
  • Nominal element resistance: 182 Ohm
  • Element length: 50 m

 

MILLICABLE/2 355/6 (HS)

Nexans ref. 10264860 - Country ref. 1034221

  • Packaging: Box (Unit)
  • Type of splice: Intergrated/hidden
  • Nominal output: 355 W
  • Nominal element resistance: 151 Ohm
  • Element length: 60 m

 

MILLICABLE/2 400/6 (HS)

Nexans ref. 10264861 - Country ref. 1034234

  • Packaging: Box (Unit)
  • Type of splice: Intergrated/hidden
  • Nominal output: 400 W
  • Nominal element resistance: 131.5 Ohm
  • Element length: 70 m

 

MILLICABLE/2 510/6 (HS)

Nexans ref. 10264862 - Country ref. 1034236

  • Packaging: Box (Unit)
  • Type of splice: Intergrated/hidden
  • Nominal output: 510 W
  • Nominal element resistance: 102.7 Ohm
  • Element length: 85 m

 

MILLICABLE/2 575/6 (HS)

Nexans ref. 10264863 - Country ref. 1034223

  • Packaging: Box (Unit)
  • Type of splice: Intergrated/hidden
  • Nominal output: 575 W
  • Nominal element resistance: 91.8 Ohm
  • Element length: 100 m

 

MILLICABLE/2 690/6 (HS)

Nexans ref. 10264894 - Country ref. 1034225

  • Packaging: Box (Unit)
  • Type of splice: Intergrated/hidden
  • Nominal output: 690 W
  • Nominal element resistance: 75.2 Ohm
  • Element length: 120 m

 

MILLICABLE/2 880/6 (HS)

Nexans ref. 10264895 - Country ref. 1034238

  • Packaging: Box (Unit)
  • Type of splice: Intergrated/hidden
  • Nominal output: 880 W
  • Nominal element resistance: 59.7 Ohm
  • Element length: 140 m

 

MILLICABLE/2 930/6 (HS)

Nexans ref. 10264896 - Country ref. 1034240

  • Packaging: Box (Unit)
  • Type of splice: Intergrated/hidden
  • Nominal output: 930 W
  • Nominal element resistance: 57 Ohm
  • Element length: 160 m

 

MILLICABLE/2 1070/6 (HS)

Nexans ref. 10264898 - Country ref. 1034242

  • Packaging: Box (Unit)
  • Type of splice: Intergrated/hidden
  • Nominal output: 1070 W
  • Nominal element resistance: 49.7 Ohm
  • Element length: 180 m

 

MILLICABLE/2 1170/6 (HS)

Nexans ref. 10264901 - Country ref. 1034227

  • Packaging: Box (Unit)
  • Type of splice: Intergrated/hidden
  • Nominal output: 1170 W
  • Nominal element resistance: 44.4 Ohm
  • Element length: 200 m

 

Description

Description

Standards

  • Product
    IEC 60800
  • Test
    IEC 60332-1
  • International
    IEC 60335-2-96

Thin twin conductor heating cable units for both renovation and new buildings. The units can be installed in two different ways:

1. MILLICABLE™ in combination with MILLICLICK™ boards. MILLICABLE™ can be installed directly under wooden floor coverings like parquet, laminate etc. without any use of concrete or levelling compound. The MILLICLICK™ boards have pre-cut slots for the cable, which makes the installation very easy to perform. The boards are placed on a stable and levelled subfloor. By using MILLICLICK™ boards, the area power will be 60 W/m². Install standard parquet underlay between the parquet and the MILLICLICK™ boards.

2. MILLICABLE™ installed as a conventional heating cable. MILLICABLE™ is installed as a freely laid cable and attached to the subfloor in the planned C-C distance. The heating cable is then covered with screed or concrete, minimum thickness 5 mm, where the entire cable must be covered.

 

Minimum installation temperature (without any precautions) 0 °C.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Type of conductor
Solid, Class 1
Insulation
FEP
Drain wire
Solid tinned copper
Screen
Conductive polymer

Dimensional characteristics

Dimensional characteristics

Approximate weight per piece
- kg
Outer Diameter
4 mm

Electrical characteristics

Electrical characteristics

Operating voltage
230 V

Usage characteristics

Usage characteristics

Flame retardant
IEC 60332-1
Length of cold lead
3.5 m
Output
6 W/m

Resources

Resources

Documentation

Related products

Accessories, series resistance heating cables

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close