MILLICABLE/2 510/6 (HS)

Description

Description

Standards

  • International
    IEC 60332-1; IEC 60335-2-96; IEC 60800

Thin twin conductor heating cable units for both renovation and new buildings. The units can be installed in two different ways:

1. MILLICABLE™ in combination with MILLICLICK™ boards. MILLICABLE™ can be installed directly under wooden floor coverings like parquet, laminate etc. without any use of concrete or levelling compound. The MILLICLICK™ boards have pre-cut slots for the cable, which makes the installation very easy to perform. The boards are placed on a stable and levelled subfloor. By using MILLICLICK™ boards, the area power will be 60 W/m². Install standard parquet underlay between the parquet and the MILLICLICK™ boards.

2. MILLICABLE™ installed as a conventional heating cable. MILLICABLE™ is installed as a freely laid cable and attached to the subfloor in the planned C-C distance. The heating cable is then covered with screed or concrete, minimum thickness 5 mm, where the entire cable must be covered.

 

Minimum installation temperature (without any precautions) 0 °C.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Number of conductors
2
Type of conductor
Solid, Class 1
Insulation
FEP
Drain wire
Solid tinned copper
Screen
Conductive polymer
Outer sheath
PVC
Sheath colour
Black
Type of splice
Intergrated/hidden

Dimensional characteristics

Dimensional characteristics

Approximate weight per piece
- kg
Outer Diameter
4 mm
Maximum outer diameter
4.2 mm
Approximate net weight
2.8 kg

Electrical characteristics

Electrical characteristics

Nominal output
510 W
Nominal element resistance
102.7 Ohm
Max. element resistance
112.9 Ohm
Min. element resistance
97.5 Ohm
Operating voltage
230 V

Usage characteristics

Usage characteristics

Element length
85 m
Flame retardant
IEC 60332-1
Length of cold lead
3.5 m
Output
6 W/m

Resources

Resources

Documentation

Declaration of Performance

  • Declaration of Performance n� : 1000026-NOLA
  • Certification Date : 1/23/17
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 0402
  • Declared performance : Eca

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close