FL-EXXE Inntak 1kV

Products

FL-EXXE 1 kV 4G50A

Nexans ref. 10581063 - Country ref. 1007402

  • Packaging: m
  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 31.0 mm
  • Approximate weight: 0.9 kg/m
  • Permissible current rating in open air: 170 A
  • Permissible current rating when buried: 190 A
  • Zero sequence resistance at 20°C: 2.56 Ohm/km
  • Capacity of phase cores approx.: 0.08 µF / km
  • Maximum Pulling Tension: 6 kN

 

FL-EXXE 1 kV 4G240A

Nexans ref. 10581062 - Country ref. 1007406

  • Packaging: m
  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 62.7 mm
  • Approximate weight: 3.9 kg/m
  • Permissible current rating in open air: 505 A
  • Permissible current rating when buried: 465 A
  • Zero sequence resistance at 20°C: 0.5 Ohm/km
  • Capacity of phase cores approx.: 0.1 µF / km
  • Maximum Pulling Tension: 28.8 kN

 

Description

Description

Power distribution cable, designated for entry point installation or other general outdoor use (UV-resistant).

The cable is halogen free, TPI insulated and  PE sheathed. Each phase having insulation and an outer sheath.

The cable can be placed directly in soil.

The conductor is made of Low Carbon Aluminum, reducing the carbon footprint of the Cable compared to standard aluminum. 

Every part of the cable is reciclable due to the utilization of Thermoplastic insulation, TPI.

The outer sheath consist of at least 30% recycled PE.

 

When laying at a lower temperature than 0°C, care must be taken to avoid damage to the outer sheath. It is especially important that the cable is not exposed to impact at temperatures below 0 °C.

When laying at a lower temperature than -10 °C, the cable should be preheated before laying.

If the cable is cut and not installed immediately, each phase must be sealed, to prevent water intrusion.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Stranded class 2
Conductor shape
Round, stranded

Dimensional characteristics

Dimensional characteristics

Number of cores
4

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close