TSLF (HD) - MP 24 - 36kV three core with red searchable marking stripe

Products

TSLF(HD) 24kV 3x1x50A MP

Nexans ref. 10564393 - Country ref. 1087813

  • Packaging: Drum (500m)
  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 58.2 mm
  • Approximate weight: 2.06 kg/m
  • Perm. current rating buried 15°C - trefoil formation: 180 A
  • Perm. current rating in air 25°C - trefoil formation: 190 A
  • Maximum Pulling Tension: 4.5 kN

 

TSLF(HD) 24kV 3x1x95A MP

Nexans ref. 10567117

  • Packaging: Drum (500m)
  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 65.9 mm
  • Approximate weight: 2.87 kg/m
  • Perm. current rating buried 15°C - trefoil formation: 265 A
  • Perm. current rating in air 25°C - trefoil formation: 295 A
  • Maximum Pulling Tension: 8.55 kN

 

TSLF(HD) 24kV 3x1x150A MP

Nexans ref. 10564616 - Country ref. 1087815

  • Packaging: Drum (500m)
  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 72.6 mm
  • Approximate weight: 3.59 kg/m
  • Perm. current rating buried 15°C - trefoil formation: 340 A
  • Perm. current rating in air 25°C - trefoil formation: 385 A
  • Maximum Pulling Tension: 13.5 kN

 

TSLF(HD) 24kV 3x1x240A MP

Nexans ref. 10567118

  • Packaging: Drum (500m)
  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 82.1 mm
  • Approximate weight: 4.94 kg/m
  • Perm. current rating buried 15°C - trefoil formation: 445 A
  • Perm. current rating in air 25°C - trefoil formation: 525 A
  • Maximum Pulling Tension: 21.6 kN

 

Description

Description

Standards

  • Product
    HD 620.10K

User benefits:

Diffusion free high voltage cable.

Avoids growth of watertrees in the XLPE insulation and increases the lifetime of the cable.

Sheath integrity may be tested while on drum, before backfilling, in plastic pipes etc.

Screen section: Value given is the physical cross section of the copper wires in the screen of one core.

 

Usage:

Indoor

Underground

Outdoors

Intended for high voltage energy distribution

Fire propertirs:

Halogen free

Cable marking:

NEXANS NS TSLF 12 kV 1 x mm²/mm² MONTH YEAR

Lifemark

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Stranded class 2

Dimensional characteristics

Dimensional characteristics

Number of cores
3

Electrical characteristics

Electrical characteristics

Maximum operating voltage
24 kV
Rated Voltage Uo/U (Um)
12 / 20 (24) kV

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*