TSLF 72 - 170kV singel core
TSLF 72 - 170kV singel core
Metal screened cable with aluminium sheath and outer semiconducting layer
Read moreTSLF 72 kV 1x150A
Nexans ref.
- Packaging: Drum (m)
- Conductor cross-section: 150 mm²
- Conductor diameter: 14.1 mm
- Diameter over insulation: 40.4 mm
- Earth conductor cross section: - mm²
- Nominal outer diameter: 51.0 mm
- Approximate weight: 2.3 kg/m
- Maximum operating voltage: 72 kV
- Rated Voltage Uo/U (Um): 36/66 (72,5) kV
- Bending factor when installed: - (xD)
TSLF 72kV 1x240A
Nexans ref. 10132941 - Country ref. 1007559
- Packaging: Drum (m)
- Conductor cross-section: 240 mm²
- Conductor diameter: 18.2 mm
- Diameter over insulation: 44.5 mm
- Earth conductor cross section: 35 mm²
- Nominal outer diameter: 55.2 mm
- Approximate weight: 2.76 kg/m
- Maximum operating voltage: 72 kV
- Rated Voltage Uo/U (Um): 36/66 (72,5) kV
- Bending factor when installed: - (xD)
TSLF 72 kV 1x240A 14 mm insulation
Nexans ref. 10239174
- Packaging: Drum (m)
- Conductor cross-section: 240 mm²
- Conductor diameter: 18.2 mm
- Diameter over insulation: 48.5 mm
- Earth conductor cross section: - mm²
- Nominal outer diameter: 60.0 mm
- Approximate weight: 3.17 kg/m
- Maximum operating voltage: 72 kV
- Rated Voltage Uo/U (Um): 36/66 (72,5) kV
- Bending factor when installed: - (xD)
TSLF 72 kV 1x400A
Nexans ref. 10094413
- Packaging: Drum (m)
- Conductor cross-section: 400 mm²
- Conductor diameter: 23.6 mm
- Diameter over insulation: 49.9 mm
- Earth conductor cross section: 35 mm²
- Nominal outer diameter: 61.0 mm
- Approximate weight: 3.5 kg/m
- Maximum operating voltage: 72 kV
- Rated Voltage Uo/U (Um): 36/66 (72,5) kV
- Bending factor when installed: 10 (xD)
TSLF 72 kV 1x400A 14 mm insulation
Nexans ref. 10572548
- Packaging: Drum (m)
- Conductor cross-section: 400 mm²
- Conductor diameter: 23.6 mm
- Diameter over insulation: 53.9 mm
- Earth conductor cross section: - mm²
- Nominal outer diameter: 65.0 mm
- Approximate weight: 3.8 kg/m
- Maximum operating voltage: 72 kV
- Rated Voltage Uo/U (Um): 36/66 (72,5) kV
- Bending factor when installed: - (xD)
TSLF 72 kV 1x630A
Nexans ref. 10216095
- Packaging: Drum (m)
- Conductor cross-section: 630 mm²
- Conductor diameter: 30.4 mm
- Diameter over insulation: 56.7 mm
- Earth conductor cross section: 50 mm²
- Nominal outer diameter: 69.0 mm
- Approximate weight: 4.64 kg/m
- Maximum operating voltage: 72 kV
- Rated Voltage Uo/U (Um): 36/66 (72,5) kV
- Bending factor when installed: - (xD)
TSLF 72 kV 1x800A
Nexans ref.
- Packaging: Drum (m)
- Conductor cross-section: 800 mm²
- Conductor diameter: 34.7 mm
- Diameter over insulation: 61.5 mm
- Earth conductor cross section: - mm²
- Nominal outer diameter: 74.0 mm
- Approximate weight: 5.56 kg/m
- Maximum operating voltage: 72 kV
- Rated Voltage Uo/U (Um): 36/66 (72,5) kV
- Bending factor when installed: - (xD)
TSLF 72 kV 1x800A 11mm isol
Nexans ref.
- Packaging: Drum (m)
- Conductor cross-section: 800 mm²
- Conductor diameter: 34.7 mm
- Diameter over insulation: 59.5 mm
- Earth conductor cross section: - mm²
- Nominal outer diameter: 72.0 mm
- Approximate weight: 5.4 kg/m
- Maximum operating voltage: 72 kV
- Rated Voltage Uo/U (Um): 36/66 (72,5) kV
- Bending factor when installed: - (xD)
TSLF 72 kV 1x1000A
Nexans ref.
- Packaging: Drum (m)
- Conductor cross-section: 1000 mm²
- Conductor diameter: 38.7 mm
- Diameter over insulation: 65.5 mm
- Earth conductor cross section: - mm²
- Nominal outer diameter: 78.0 mm
- Approximate weight: 6.39 kg/m
- Maximum operating voltage: 72 kV
- Rated Voltage Uo/U (Um): 36/66 (72,5) kV
- Bending factor when installed: - (xD)
TSLF 72 kV 1x1000A (15 mm isol)
Nexans ref.
- Packaging: Drum (m)
- Conductor cross-section: 1000 mm²
- Conductor diameter: 38.7 mm
- Diameter over insulation: 71.6 mm
- Earth conductor cross section: - mm²
- Nominal outer diameter: 75.0 mm
- Approximate weight: 6.9 kg/m
- Maximum operating voltage: 72 kV
- Rated Voltage Uo/U (Um): 36/66 (72,5) kV
- Bending factor when installed: - (xD)
TSLF 72 kV 1x1200A
Nexans ref. 10196295
- Packaging: Drum (m)
- Conductor cross-section: 1200 mm²
- Conductor diameter: 41.7 mm
- Diameter over insulation: 68.5 mm
- Earth conductor cross section: - mm²
- Nominal outer diameter: 81.0 mm
- Approximate weight: 7.03 kg/m
- Maximum operating voltage: 72 kV
- Rated Voltage Uo/U (Um): 36/66 (72,5) kV
- Bending factor when installed: - (xD)
TSLF 72 kV 1x1200A (14 mm isol og 30 mm² skjerm)
Nexans ref.
- Packaging: Drum (m)
- Conductor cross-section: 1200 mm²
- Conductor diameter: 41.7 mm
- Diameter over insulation: 72.5 mm
- Earth conductor cross section: - mm²
- Nominal outer diameter: 85.0 mm
- Approximate weight: 7.34 kg/m
- Maximum operating voltage: 72 kV
- Rated Voltage Uo/U (Um): 36/66 (72,5) kV
- Bending factor when installed: - (xD)
TSLF 72 kV 1x1200A 12 mm isol og 95 mm² skjerm
Nexans ref.
- Packaging: Drum (m)
- Conductor cross-section: 1200 mm²
- Conductor diameter: 41.7 mm
- Diameter over insulation: 68.5 mm
- Earth conductor cross section: - mm²
- Nominal outer diameter: 81.0 mm
- Approximate weight: 7.5 kg/m
- Maximum operating voltage: 72 kV
- Rated Voltage Uo/U (Um): 36/66 (72,5) kV
- Bending factor when installed: - (xD)
TSLF 170 kV 1x400A
Nexans ref. 10557321
- Packaging: Drum (m)
- Conductor cross-section: 400 mm²
- Conductor diameter: 23.6 mm
- Diameter over insulation: 62.4 mm
- Earth conductor cross section: 95 mm²
- Nominal outer diameter: 76.0 mm
- Approximate weight: 5.1 kg/m
- Maximum operating voltage: 170 kV
- Rated Voltage Uo/U (Um): 87/150 (170) kV
- Bending factor when installed: 10 (xD)
TSLF 170 kV 1x630A
Nexans ref. 10267694
- Packaging: Drum (m)
- Conductor cross-section: 630 mm²
- Conductor diameter: 30.4 mm
- Diameter over insulation: 67.2 mm
- Earth conductor cross section: - mm²
- Nominal outer diameter: 81.0 mm
- Approximate weight: 6.15 kg/m
- Maximum operating voltage: 170 kV
- Rated Voltage Uo/U (Um): 87/150 (170) kV
- Bending factor when installed: - (xD)
TSLF 170 kV 1x800A
Nexans ref. 10260708
- Packaging: Drum (m)
- Conductor cross-section: 800 mm²
- Conductor diameter: 34.7 mm
- Diameter over insulation: 71.5 mm
- Earth conductor cross section: - mm²
- Nominal outer diameter: 85.0 mm
- Approximate weight: 6.87 kg/m
- Maximum operating voltage: 170 kV
- Rated Voltage Uo/U (Um): 87/150 (170) kV
- Bending factor when installed: - (xD)
TSLF 170 kV 1x1000A
Nexans ref.
- Packaging: Drum (m)
- Conductor cross-section: 1000 mm²
- Conductor diameter: 38.7 mm
- Diameter over insulation: 76.0 mm
- Earth conductor cross section: - mm²
- Nominal outer diameter: 90.0 mm
- Approximate weight: 7.82 kg/m
- Maximum operating voltage: 170 kV
- Rated Voltage Uo/U (Um): 87/150 (170) kV
- Bending factor when installed: - (xD)
TSLF 170 kV 1x1200A
Nexans ref. 10210291
- Packaging: Drum (m)
- Conductor cross-section: 1200 mm²
- Conductor diameter: 41.7 mm
- Diameter over insulation: 79.0 mm
- Earth conductor cross section: - mm²
- Nominal outer diameter: 93.0 mm
- Approximate weight: 8.55 kg/m
- Maximum operating voltage: 170 kV
- Rated Voltage Uo/U (Um): 87/150 (170) kV
- Bending factor when installed: - (xD)
TSLF 170 kV 1x1600A
Nexans ref. 10215094
- Packaging: Drum (m)
- Conductor cross-section: 1600 mm²
- Conductor diameter: 48.6 mm
- Diameter over insulation: 85.9 mm
- Earth conductor cross section: - mm²
- Nominal outer diameter: 101.0 mm
- Approximate weight: 10.3 kg/m
- Maximum operating voltage: 170 kV
- Rated Voltage Uo/U (Um): 87/150 (170) kV
- Bending factor when installed: - (xD)
TSLF 170 kV 1x2000A
Nexans ref.
- Packaging: Drum (m)
- Conductor cross-section: 2000 mm²
- Conductor diameter: 57.2 mm
- Diameter over insulation: 94.5 mm
- Earth conductor cross section: - mm²
- Nominal outer diameter: 110.0 mm
- Approximate weight: 12.5 kg/m
- Maximum operating voltage: 170 kV
- Rated Voltage Uo/U (Um): 87/150 (170) kV
- Bending factor when installed: - (xD)
Description
Description
Standards
-
TestIEC 60840
User benefits:
Diffusion free high voltage cable
Avoids growth of watertrees in the XLPE insulation and increases the lifetime of the cable.
Sheath integrity may be tested while on drum, before backfilling, in plastic pipes etc.
Meter marks
Screen section: Value given is the physical cross section of the copper wires in the screen.
Usage: Indoor, Underground, Outdoors
Intended for high voltage energy distribution
Fire properties:
Halogenfree
Cable marking:
NEXANS NS TSLF kV 1 x mm²/mm² MONTH YEAR, metermarks
Lifemark
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania